• Do not alter the mixing ratios.
• Chamfering the concrete edge helps to reduce thermal cracking. The potential for cracking can be reduced when chamfers are formed in accordance with the application procedures.
• Do not apply at temperatures below +5 °C.
• Working and reaction times of resin-based systems are affected by ambient and substrate temperature and by relative humidity. Low temperatures slow down the reaction, which extends the usable life and working time.
• High temperatures accelerate the reaction, and the times stated above are shortened accordingly. For the material to complete curing, the ambient and substrate temperatures must not fall below the minimum permitted temperature.
• For exterior applications, the surface must be protected from sun, wind, rain or frost for the first 24 hours. • Do not use a vibrator when placing the material.
• Make sure that the material has been stored at an ambient temperature of up to 25 °C for at least 48 hours before use. Failure to do so will result in a significant reduction in usable life at high temperatures.
• Make sure that the material is mixed in the correct mixing ratios.
• Always use a feed hopper/head box.
• Do not add solvent, water or any other material to the grout.
• Grout prepared from material stored under unsuitable conditions will show reduced flowability and low strength development.