ClvSeal PU INJECTION
Single-Component, Polyurethane-Based, Elastic Injection Material
ClvSeal PU INJECTION is a single-component, low-viscosity, closed-cell injection resin that reacts with moisture and water. It is a special polyurethane-based injection resin used to stop pressurised or non-pressurised water seeping through cracks in concrete.
• Easy to apply.
• Performs effectively in sealing cracks, voids and joints in concrete.
• Adjustable reaction time.
• Hydrophobic.
• Owing to its low viscosity, penetrates very well into hairline cracks.
• Solvent-free.
• Reacts with water to stop leaks.

FEATURES AND BENEFITS
-
• Easy to apply.
• Performs effectively in sealing cracks, voids and joints in concrete.
• Adjustable reaction time.
• Hydrophobic.
• Owing to its low viscosity, penetrates very well into hairline cracks.
• Solvent-free.
• Reacts with water to stop leaks.
FIELDS OF APPLICATION
-
• Retaining walls
• Foundations
• Cracked walls
• Below-ground surfaces of garages and houses
• Dams
• Foundations and underground passages
• Wastewater and sewerage systems
• Storage facilities
• In fill layers and joints
Product Details
The consumption of ClvSeal PU INJECTION corresponds to the quantity required to completely fill the cracks and voids.
Supplied as a kit in 25 L + 2.50 L metal pails; beige transparent-yellow in colour.
Store the product in its unopened original packaging at temperatures between +5 °C and +25 °C for a maximum of 12 months. Once opened, use the product as soon as possible.
| PROPERTY | TEST METHOD | VALUE |
|---|---|---|
| Product Type | Clever Lab. | Polyurethane injection resin |
| Density | ASTM D1475 / EN ISO 2811-1 (+20 °C) | 1.10 ±0.04 g/cm³ |
| Viscosity | ASTM D4287 (+25 °C) | 200 cP |
| Gloss | Clever Lab. | Semi-gloss |
| Thinning | Clever Lab. | Not recommended |
| Solids Content | Clever Lab. | 100% |
| Flash Point | Clever Lab. | +145 °C |
| Full Drying Time | Clever Lab. | 2–4 h |
* Viscosity measured at +25 °C in accordance with EN ISO 3219. Viscosity decreases as temperature rises.
| PROPERTY | TEST METHOD | VALUE |
|---|---|---|
| Colour | Clever Lab. | Transparent, yellow |
| Density | ASTM D1475 / EN ISO 2811-1 (+20 °C) | 0.95 g/cm³ |
| Viscosity | ASTM D2196-86 / EN ISO 3219 (+25 °C) | ~15 cP |
| Flash Point | Clever Lab. | +145 °C |
* Viscosity measured at +25 °C in accordance with EN ISO 3219. Viscosity decreases as temperature rises.
Application
• SURFACE PREPARATION
Before application, all flexible and loose parts and dust must be removed from the cracks. Cracks wider than 3 mm must be sealed with suitable repair materials. The positions of the packers (injectors) are determined according to where the leak originates. Packers are installed at an angle of 45 degrees. Packers must be driven in to a depth of half the thickness of the reinforced concrete. The spacing between packers may be between 15 cm and 90 cm.
• PRIMING
No priming is required if cleaning has been carried out properly as described above.
• APPLICATION
PU INJ CATALYST (catalyst) must be thoroughly mixed beforehand. ClvSeal PU INJECTION is made ready for use by mixing it with the specified quantity of catalyst. The catalyst ratio must be determined on site according to the crack, the rate of water ingress and the weather conditions. The catalyst can be used at between 5% and 10%. The application pressure varies between 14 and 200 bar. Start the injection at the first packer. Start at low pressure and increase the pressure until resin begins to overflow. Once resin overflows, move on to the next packer. During injection, the resin injected through all the packers will emerge as pure resin from the leaking cracks in the reinforced concrete. The application is then completed. The consumption of ClvSeal PU INJECTION corresponds to the quantity required to completely fill the cracks and voids.
• Not recommended for unsound substrates.
• Not suitable for waterproofing swimming pools containing chemically treated water.