PU 100
Fast-Curing, Single-Component Polyurethane Waterproofing Material
PU 100 is a single-component, fast-curing, polyurethane-based liquid waterproofing material.
• Fast curing.
• Provides a thick, bubble-free layer.
• Suitable for single-coat application.
• Easy to apply (by brush, roller or airless spray).
• Forms a seamless, monolithic membrane that does not create joints or cause leaks when applied.
• Resistant to permanent water contact.
• Retains its mechanical properties between −40 °C and +90 °C.
• Effectively permeable to water vapour. Owing to its breathable structure, it does not cause moisture to accumulate beneath the layer.
• If damaged, the material can be repaired quickly and easily with PU 100.
• Excellent chemical resistance.
• Excellent UV resistance.
• Cures by reaction with atmospheric moisture to form an elastic, thick and durable film.
![]()
FEATURES AND BENEFITS
-
• Fast curing.
• Provides a thick, bubble-free layer.
• Suitable for single-coat application.
• Easy to apply (by brush, roller or airless spray).
• Forms a seamless, monolithic membrane that does not create joints or cause leaks when applied.
• Resistant to permanent water contact.
• Retains its mechanical properties between −40 °C and +90 °C.
• Effectively permeable to water vapour. Owing to its breathable structure, it does not cause moisture to accumulate beneath the layer.
• If damaged, the material can be repaired quickly and easily with PU 100.
• Excellent chemical resistance.
• Excellent UV resistance.
• Cures by reaction with atmospheric moisture to form an elastic, thick and durable film.
FIELDS OF APPLICATION
-
• Exposed roofs.
• Polyurethane insulation foams
• Terraces, verandas and balconies.
• Wet rooms beneath tiles (bathrooms, kitchens, etc.).
• Car parks.
• Gypsum and cement boards.
• Lightweight roofs made of metal or fibre cement.
• Interior and exterior applications.
• EPDM membranes.
Product Details
Total consumption: 1.80–2.60 kg/m²
Grey, in 5 kg and 25 kg metal pails.
Store the product in its unopened original packaging at temperatures between +5 °C and +25 °C for a maximum of 12 months. Once opened, use the product as soon as possible.
• Concrete strength class: C20/25
• Substrate moisture content: W <10%
• Temperature: +5 °C to +35 °C
• Relative humidity: <85%
| PROPERTY | TEST METHOD | VALUE |
|---|---|---|
| Chemical Base | Clever Lab. | Single-component polyurethane |
| Density | ASTM D1475 / DIN 53217 / ISO 2811 (+20 °C) | 1.40 ± 0.05 g/cm³ |
| Viscosity | ASTM D4287 (+25 °C) | 2000–5000 cP |
| Flash Point | ASTM D93 | 35 °C |
| Water Vapour Permeability | ASTM E96 | 0.8 g/(m²·h) |
| Gloss | Clever Lab. | Semi-gloss |
| Application Temperature | Clever Lab. | +5 °C to +35 °C |
| Resistance to Heat Ageing | Clever Lab. | 100 days at +80 °C |
| Heat Shock Resistance | Clever Lab. | 200 °C – Pass |
| Solids Content | Clever Lab. | 85% (±5) |
| Hardness | ASTM D2240 / DIN 53505 / EN ISO 868 | 70 Shore A |
| Elongation at Break | ASTM D412 / EN ISO 527-3 (+23 °C) | >400% |
| Tensile Strength at Break | ASTM D412 / EN ISO 527-3 (+23 °C) | >6.5 N/mm² |
| Adhesion to Concrete | ASTM D4541 (+23 °C) | >2 N/mm² |
| Perm. Set after 300% Elong. | ASTM D412 | <3% |
| QUV | ASTM G53 | 2000 h – Pass |
| Service Temperature | Clever Lab. | −40 °C to +90 °C |
| Initial Curing Time | 25 °C / 55% RH | 2–3 h |
| Waiting Time between Coats | Clever Lab. | 2–6 h |
Application
• SURFACE PREPARATION
Before application, all contaminants that impair bonding and adhesion, such as oil, grease, paraffin residues, cement laitance, loose particles, release agents and old cured membranes, must be removed from the substrate. After washing with high-pressure water, the substrate must be dried thoroughly. Surface defects must be repaired with suitable products. Apply the second coat at least 6 and at most 48 hours after applying the first coat. If the second coat cannot be applied within the specified time, consult the CLEVER POLYMERS Technical Department for information and solutions before proceeding. Consult our Technical Department regarding thinning.
• PRIMING
For absorbent substrates such as concrete, cement or screed, use PU PRIMER 200 or ClvSeal EP PRIMER 617. On damp substrates, ClvSeal EP PRIMER 625 should be preferred. On non-absorbent substrates such as metal and ceramics, use PRIMER T. For detailed information, refer to the primer table.
• APPLICATION
Before use, open the container and mix for 2–3 minutes with a low-speed mixer. For spray application, add a maximum of 5–7% CLEVER 001. Pour the product onto the previously primed surface and spread it in one or two coats with a roller or brush until the entire surface is covered. Apply the second coat at least 8 and at most 48 hours after applying the first coat. If the second coat cannot be applied within the specified time, consult the CLEVER POLYMERS Technical Department for information and solutions before proceeding. Consult our Technical Department regarding thinning.
• To extend the durability and service life of polyurethane waterproofing products applied in exposed areas subject to weathering or foot traffic, they must be overcoated with ClvSeal PU 650 TC-1K flexible aliphatic top coat.
• Not recommended for unsound substrates.
• Not suitable for waterproofing swimming pools containing chemically treated water.