PU 120
Single-Component, Polyurethane-Based Liquid Waterproofing Material
PU 120 is a single-component, polyurethane-based liquid waterproofing material. It cures by reaction with atmospheric moisture to form an elastic, durable film.
• Easy to apply (by brush, roller or spray).
• Forms a seamless, monolithic film that does not create joints or cause leaks when applied.
• Resistant to permanent water contact.
• Retains its mechanical properties between −30 °C and +90 °C.
• Effectively permeable to water vapour. Owing to its breathable structure, it does not cause moisture to accumulate beneath the layer.
• If damaged, the material can be repaired quickly with PU 120.
• UV-resistant.
![]()
FEATURES AND BENEFITS
-
• Easy to apply (by brush, roller or spray).
• Forms a seamless, monolithic film that does not create joints or cause leaks when applied.
• Resistant to permanent water contact.
• Retains its mechanical properties between −30 °C and +90 °C.
• Effectively permeable to water vapour. Owing to its breathable structure, it does not cause moisture to accumulate beneath the layer.
• If damaged, the material can be repaired quickly with PU 120.
• UV-resistant.
FIELDS OF APPLICATION
-
• Terraces, verandas and balconies,
• Wet rooms beneath tiles (bathrooms, kitchens, etc.),
• Interior and exterior applications,
• Irrigation channels,
• Bituminous membranes,
• Gypsum and cement boards,
• Roofs with a protective covering.
Product Details
• First coat (min.): 0.60–0.75 kg/m²
• Second coat (min.): 0.60–0.75 kg/m²
• Spray application (per coat): 0.75–0.90 kg/m²
• Total consumption (minimum): 1.20–1.50 kg/m²
Grey, in 5 kg and 25 kg metal tins.
Store the product in its unopened original packaging at temperatures between +5 °C and +25 °C for a maximum of 12 months. Once opened, use the product as soon as possible.
• Concrete strength class: C20/25
• Substrate moisture content: W<5%
• Temperature: +5 °C to +35 °C
• Relative humidity: <85%
| PROPERTY | TEST METHOD | VALUE |
|---|---|---|
| Product Type | Clever Lab. | Single-component polyurethane |
| Density | ASTM D1475 / EN ISO 2811-1 (+20 °C) | 1.45 ± 0.05 g/cm³ |
| Viscosity | ASTM D4287 (+25 °C) | 3,000–6,000 cP |
| Water Vapour Permeability | ASTM E96 | 0.8 g/(m²·h) |
| Gloss | Clever Lab. | Semi-gloss |
| Application Temperature | Clever Lab. | +5 °C to +35 °C |
| Resistance to Heat Ageing | Clever Lab. | 100 days at +80 °C |
| Heat Shock Resistance | Clever Lab. | 200 °C – Pass |
| Solids Content | Clever Lab. | 85% (±5) |
| Hardness | ASTM D2240 | 65 Shore A |
| Elongation at Break | ASTM D412 / DIN 52455 (+23 °C) | >400% |
| Tensile Strength at Break | ASTM D412 / DIN 52455 (+23 °C) | >5 N/mm² |
| Adhesion to Concrete | ASTM D4541 | >2 N/mm² |
| QUV | ASTM G53 | 2000 h – Pass |
| Service Temperature | Clever Lab. | −30 °C to +90 °C |
| Initial Drying Time | 25 °C / 55% RH | 6 h |
| Waiting Time between Coats | Clever Lab. | 6–24 h |
Application
• SURFACE PREPARATION
Before application, all contaminants that impair bonding and adhesion, such as oil, grease, paraffin residues, cement laitance, loose particles, release agents and old cured membranes, must be removed from the substrate. After washing with high-pressure water, the substrate must be dried thoroughly. Surface defects must be repaired with suitable products.
• PRIMING
For absorbent substrates such as concrete, cement or screed, use PU PRIMER 200 or ClvSeal EP PRIMER 617. On damp substrates, ClvSeal EP PRIMER 625 should be preferred. On non-absorbent substrates such as metal and ceramics, use PRIMER T. For detailed information, refer to the primer table.
• APPLICATION
Before use, open the container and mix for 2–3 minutes with a low-speed mixer. For spray application, add a maximum of 5–7% CLEVER 001. Pour the product onto the previously primed surface and spread it in at least 2 coats with a roller, squeegee or brush until the entire surface is covered. Apply the second coat at least 6 and at most 24 hours after applying the first coat. If the second coat cannot be applied within the specified time, consult the CLEVER POLYMERS Technical Department for information and solutions before proceeding. In cold weather, the use of ACC CATALYST is recommended, if desired, to accelerate drying. Consult our Technical Department regarding thinning.
• To extend the durability and service life of polyurethane waterproofing products applied in exposed areas subject to weathering or foot traffic, they must be overcoated with ClvSeal PU 650 TC-1K flexible aliphatic top coat.
• Not recommended for unsound substrates.
• Not suitable for waterproofing swimming pools containing chemically treated water.